New products are available now. These products are compatible with Ferrotec’s seals. Click on the following Cross Reference Sheet.
Cantilever Series FMB-***-C***
Solid shaft (equipped with shaft)Shaft diameter :10Shaft diameter :12Shaft diameter :15Bearing arrangement :Cantilever (One side)Water cooling:Water cooling
Round straightFlat cutKey groove
Round straightFlat cutKey groove
This is based on the FMB type, with the magnetic fluid arranged in the vacuum side. This is suitable for active gas applications.
For shaft diameter of 15mm or over, end face flat processing is not covered by this specification.
CAD Download
You can use CAD data downloading after making a member account.
Product Specification
FMB-010-C | FMB-012-C | FMB-015-C | |
---|---|---|---|
Inquiry | Inquiry | Inquiry | Inquiry |
A [mm] | 10g6-0.005 -0.014 |
12g6-0.006 -0.017 |
15g6-0.006 -0.017 |
B [mm] | 134 | 134 | 155 |
C [mm] | 30 | 30 | 40 |
D [mm] | 79 | 79 | 85 |
E [mm] | 64f7-0.030 -0.060 |
64f7-0.030 -0.060 |
74f7-0.030 -0.060 |
F [mm] | 8 | 8 | 8 |
H [mm] | 52f7-0.030 -0.060 |
52f7-0.030 -0.060 |
56f7-0.030 -0.060 |
I [mm] | 40 | 40 | 47 |
J | 6-Φ6.5PCD54 | 6-Φ6.5PCD54 | 6-Φ6.5PCD61 |
K | 4-M6 deep 10PCD42 | 4-M6 deep 10PCD42 | 4-M6 deep 10PCD47 |
L[mm] | 20 | 20 | 20 |
O (O-ring used) | G35 | G35 | G40 |
Water cooling option | 2-Rc1/8 | 2-Rc1/8 | 2-Rc1/8 |
G [mm] | 12 | 12 | 12 |
Shaft option1 | Key groove (both ends) | Key groove (both ends) | Key groove (both ends) |
S [mm] | 16 | 19 | 26 |
T [mm] | 2.5+0.1 0 |
2.5+0.1 0 |
3+0.1 0 |
U [mm] | 4+0.040 0 |
4+0.040 0 |
5+0.040 0 |
Shaft option2 | Flat cut (both ends) | Flat cut (both ends) | |
S [mm] | 15 | 18 | |
V [mm] | 1 | 1 | |
Max. rotation rate [rpm] (*1) (*2) (with water cooling) |
4800 (16000) |
4800 (16000) |
3400 (11000) |
Rated rotation rate [rpm] (*1) (*3) (with water cooling) |
2200 | 2700 | 3300 |
Allowable axial load [N] (*4) | 29 | 29 | 29 |
Allowable radial load [N] (*5) | 55 | 76 | 83 |
Mass [kg] | 1 | 1 | 1.5 |
Starting torque [N∙m] (*1) (*6) | 0.054 | 0.054 | 0.11 |
Allowable transmission torque [N∙m] | 9 | 13 | 30 |
- (*1): This is the numerical value when a magnetic fluid of standard vacuum specification (A type) is used. The value is different when a magnetic fluid of anti-corrosion specification (F type) or low vapor pressure and anti-corrosion specification (U type) is used.
- (*2): The allowable rotation rate when no load is applied to the shaft.
- (*3): The allowable rotation rate when the allowable radial load is applied.
-
(*4): The maximum axial load that can be applied to the center of magnetic fluid seal shaft.
If the load combined with the radial load is applied, or if the load point is off the center of the shaft, please contact us from the Inquiry Form for the magnetic fluid and describe the load conditions in the form. -
(*5): The maximum radial load that can be applied to the shaft end of magnetic fluid seal.
If the load combined with the axial load is applied, or if the load point is far from the shaft end, please contact us from the Inquiry Form for the magnetic fluid and describe the load conditions in the form. - (*6): Starting torque is the maximum load torque upon starting of rotation. This is a reference value and not a guaranteed value. Recommended load torque for selecting a motor is about three times as high as the value described above.
Common Specification for Standard Products
Vacuum resistance | 1.0x10-6Pa | |
---|---|---|
Leakage rate (He) | 9.9×10-11Pa・m3/sec or less | |
Operating atmosphere (*1) | In vacuum / in inert gas / in corrosive gas | |
Materials used | Housing | SUS 304 |
Shaft | SUS 630 | |
Pole piece | SUS 630 | |
Bearing | SUJ2 | |
O-ring | FKM | |
Bearing lubricant |
Vacuum side: fluorine vacuum grease Atmosphere side: general-purpose case with rust inhibitor |
|
Standard accessories (*2) | O-ring Washer and nut (LSB Series) |
-
(*1): For application with corrosive gases, please specify a magnetic fluid of anti-corrosion specification or low vapor pressure and anti-corrosion specification.
Also, some gas types and operating conditions require different support. Please contact our sales personnel to inform us of your operating environment. -
(*2): The size of O-ring supplied is described on the page for details of each model.
Also, the LSB Series are supplied with mounting washer and nut.